UPS and data centre services in Toronto
We maintain, repair and install UPS systems and replace their batteries. We also test them under load and look after the room they sit in: precision cooling, cleaning and infrared thermography. A maintenance contract puts several sites and brands on one schedule and one report format.
Key facts
- UPS work: maintenance, batteries, 24/7 repair, installation, replacement planning
- Testing: battery readings, capacity tests, bypass transfers, load bank runs
- The room: precision cooling, cleaning, thermography, power quality
- Brands: Eaton, APC, Vertiv and Liebert, Tripp Lite, Mitsubishi, Toshiba, XPC, Delta
Services
| Service | What it covers | What you receive |
|---|---|---|
| UPS preventive maintenance | Inspection, battery readings, fans, capacitors, bypass test | Report with each reading next to the last visit |
| Installation and commissioning | Sizing check, placement, start-up, acceptance tests | Commissioning record with settings and test results |
| Battery replacement and testing | VRLA and lithium-ion strings, internal resistance, capacity tests | Block readings, date codes, recycling record |
| 24/7 emergency repair | Alarms, bypass events, failed modules, dead strings | Fault found, repair made, parts used |
| Load bank testing | Rated load and transfers on an artificial load | Readings at each load step |
| Data centre cleaning | Sub-floor, zinc whiskers, particulate around live equipment | Cleaning record by zone |
| Precision cooling maintenance | CRAC and CRAH units serving UPS and IT rooms | Service record with setpoints and readings |
| Power quality and thermography | Hot connections, harmonics at the UPS input and output | Thermal images and a ranked fault list |
| Replacement planning | End-of-life dates, options, budget | A plan with dates and costs |
| Maintenance contracts | Visit schedule and reporting across sites | One schedule, one report format |
Who we work for
Colocation and enterprise data centres, hospitals and labs, government and utility buildings, telecom rooms, broadcasters, and offices whose server room has to stay up. Mixed fleets are normal: an Eaton frame in the main UPS room, APC or Tripp Lite rack units in the closets, one plan for all of them.
UPS brands
Eaton, including Powerware, APC by Schneider Electric, Vertiv and Liebert, Tripp Lite, Mitsubishi Electric, Toshiba, XPC and Delta, single-phase and three-phase.
Common questions
Which services can be booked on the same visit?
Battery readings, a bypass transfer test and infrared thermography fit in one preventive maintenance visit. A load bank test or a full capacity test needs its own window.
Can one contract cover several sites and brands?
Yes. One contract sets the visit schedule, the response terms and the report format for every UPS on every site.
Can you work in a live data centre?
Yes. Work follows your change window and access rules. Any transfer to bypass is written into a method of procedure and agreed before the visit.
Do you test the batteries or only replace them?
Both. Every visit reads each block's voltage, internal resistance and temperature against its baseline [1]. Replacement is quoted only when the readings call for it.