UPS service for Toronto data centres and server rooms

Symetrix Canada maintains, tests and repairs UPS systems and their batteries in Toronto and across the GTA: three-phase frames in data centres, rack units in network rooms, and the battery strings behind both. Every visit ends with a written report of the readings taken, the faults found and what to budget next.

Request a quoteCall 1 (438) 800-0382
UPS power pathsUtility power feeds the rectifier, the DC bus and battery string, then the inverter and the load. A static bypass and a maintenance bypass route around the UPS.Maintenance bypassStatic bypassUtilityRectifierInverterLoadDC busBattery stringNormal: rectifier and inverterOn battery: battery string and inverterStatic bypass: utility to loadMaintenance bypass: UPS isolated
The UPS power path: utility input, rectifier, battery string, inverter, and the static and maintenance bypasses around them.

What we fix

All services

UPS brands

Single-phase and three-phase, current models and discontinued frames still in service.

How a call runs

  1. Send the detailsMake, model, serial number and what the unit is doing, by phone or the request form.
  2. Questions and a quoteA reply with the questions that matter and a price, or a technician for an emergency.
  3. The visitThe manufacturer's procedure, your site's access rules, and any bypass transfer agreed with you first.
  4. The reportReadings set against the last visit, faults found, and what to budget next, each with a price.

What the report contains

  • Input, output and bypass readings on each phase, and the load per phase
  • Every battery block: voltage, internal resistance and temperature, against its baseline [1]
  • The event log: alarms cleared and alarms still open
  • Firmware version, settings, and the age of fans and capacitors
  • What is due now, what can wait, and a price for each
Sample service reportOne report page: site and unit details, readings, findings, work done and next actions.Service reportSiteUnitDateReadingsFindingsWork doneNext actions
A sample page: each block's reading next to the last visit, drift flagged, parts due now and parts to budget.
  • 24/7Emergency line, answered day and night
  • EightUPS brands, single-phase and three-phase
  • Every blockEach battery block read against its baseline at every visit[1]
  • Twice a yearVisits on critical sites, as Vertiv's service data supports[2]
  • 100Canadian data centres listed from government and operator sources

Toronto and the GTA

Colocation suites, enterprise server rooms, hospitals and government buildings across the GTA, and further out in Ottawa, Hamilton and London.

Service area: the GTA, then Ottawa, Hamilton and LondonTorontoMississaugaMarkhamVaughanBramptonOttawaHamiltonLondon
Service area: the GTA, then Ottawa, Hamilton and London

Common questions

Who services UPS systems in Toronto data centres?

Symetrix Canada: maintenance, battery replacement and emergency repair on Eaton, APC, Vertiv and Liebert, Tripp Lite, Mitsubishi, Toshiba, XPC and Delta units across Toronto and the GTA.

How often should a data-centre UPS be serviced?

At least once a year, as Eaton recommends [3]. Critical sites book two visits a year, which Vertiv's service data supports [2].

How long do UPS batteries last?

Most APC VRLA batteries last three to five years [4]. Heat cuts that short: every 8 °C rise halves it [4].

Do you replace UPS batteries on site?

Yes. We test the string, replace single blocks or the full string, check the charger settings and take the old batteries away for recycling.

What should I send with a request?

The site address, UPS make, model and serial number, the battery setup, the last service date, any open alarms and your preferred window.